欢迎光临北京易安恒瑞科技有限公司网站!
诊断软件版本更新D
来源: | 作者:pro297a4f | 发布时间 :2023-12-27 | 1344 次浏览: | 分享到:

DIAGRA D RELEASE NOTES

All notable changes to DiagRA D will be documented in this file.

7.69.45.62573 Release (2025-10-10)

  • Bugfix: Snapshot with A2L didn't run in some cases

  • DoIP flash programming through D-PDU API is supported.

  • Save OBD configurations for all protocols in the snapshot config file

  • Bugfix: Snapshot output XML was not displayed

  • Bugfix: XSD 2.0 and 3.0 schema files were missing "not available" for MIL status

  • Implemented search highlighting for the selection of measurement values.

  • Improve layout of the settings dialog to be more consistent with spacing and control widths.

  • TCP communication:

    • Improve behaviour when the web service TCP port is currently in use by another application.

  • Bugfix in recording:

    • Empty cells were accidently added in CSV and Excel recording.

    • Values was not under the expected column headings when Infotype 0F is used in OBD Mode 9.

  • RP1210: Properly read detailed version information from API and add it to the log file.

  • Workaround for RP1210 filter limitation in Jaltest interface

  • Function 'Send diagnostic services':

    • Parameters for UDS service 0x28 CommunicationControl fixed

    • Support of DoIP through D-PDU-API

    • Results can be saved to a file

  • List of standardized DTCs updated along SAE J2012. U07xx, U08xx and C08xx DTCs added.

  • SAE J1979:

    • All new PIDs and ITIDs for OBM Euro 7 added

    • ITID 7B removed

  • SAE J1939:

    • Timeout for the reception of DM24 extended to 2 s

    • Issue with PGN 0x8100 fixed (related to raw CAN interfaces)

    • SPN 7352 and 7459 added

  • SAE J1979-2:

    • Improved presentation of test results

    • Performance when showing freeze frames improved

    • A message is displayed if no freeze frames are available

    • Flickering of data fixed

    • DIDs F51B-F51F added, DID F4AD fixed

  • SAE J1979-3:

    • Bugfix: Switching ECUs could cause data freeze in special cases


7.67.45.61458 Release (2025-06-23)

  • Output of OBD Freeze-Frames in DTC snapshot for UDS VAG fixed

  • Configuration of developer page OBD radar updated for Vitesco

  • Webservices

    • Bugfix: GetOBDFreezeFrameData provided incomplete data

    • ClearECUFaultMemory shall not pass through any ResponsePending messages

  • SAE J1979:

    • Conversion of Infotype 81 fixed, which uses signed raw data

  • SAE J1979-2:

    • Bugfix: Duplicates in list of supported DIDs in output file fixed

  • SAE J1939:

    • SPN 2432 added to SAE J1939 config file



7.67.45.61338 Release (2025-06-02)

  • Added SiL time synchronization with Vector FDX API

  • Allow to erase each history list individually

  • Activate automatic bitrate detection on CAN for interfaces with RP1210 D API

  • Vector XL-API dll updated to version 24.40.30

  • Conversion of PID $A3 for SAE J1699-3 fixed

  • Improvements and bugfixes in Webservice API

  • SAE J1939:

    • Bugfix: Snapshot could freeze under certain conditions

    • Workaround for communication issue in certain Hino trucks: SAE J1939 protocol significantly improved for raw CAN interfaces

    • SPN 21226 added to config file

  • Recording:

    • Bugfix: In an MDF file with multiple ECUs in OBD mode 1, incorrect data could be written

    • Bugfix: Each measurement value should have a unique timestamp in an MDF file

  • DiagRA Script:

    • Bugfix: DIAG::READ_VALUE_BY_NAME only ever returned first value if a group contained several values.

    • Bugfix: Add missing command DIAG::USE_CAN_FD to activate or deactivate CAN FD (if supported by currently selected VCI channel).



7.66.45.60464 Release (2025-03-05)

  • FlexRay | Extended Frame, Receive buffer extended to up to 8 kByte

  • Updated trouble code files for VAG

  • Code Clear for UDS VAG adapted to ECUs which support OBDonUDS

  • PVD/SFD:

    • Updating the service to use the latest HIL backend.

    • Fix for communication issues in Windows 11.

  • ASAP3: New UI element has been added in the Options page to keep a list of allowed IPs for ASAP3.

  • Webservice: Improved documentation on flashing PDX/ODX files.

  • Webservice: A new option has been added in setting page to choose port for Web Service.

  • Fixed failing PDF conversion when the folder/file contained non-ASCII characters.

  • Bugfix: Sporadic shifts/gaps in OBD with simultaneous recording.

  • SAE J1979:

    • Many Infotypes added to Mode 9. Configuration is now compliant to SAE J1979-DA from April 2024.

  • SAE J1979-2:

    • Added Chinese translation for SAE J1979-2 Data

    • Support OBDonUDS response messages up to 8 kByte

    • Bugfix: Snapshot files of SAE J1979-2 could save unexpected header of freeze frames under certain conditions

  • SAE J1939:

    • Several data stream SPNs added to config file



7.65.44.59732 Release (2024-12-09)

  • Implemented a function on the developer pages that displays the results of the OBD radar statistics for Vitesco ECUs.

  • The option "Load last configuration" now loads the last configuration and not just the last A2L/HEX/DBC files.

  • Bugfix: Goepel CAN FD: Longer RX frames (> 184 Byte) may not be cached correctly.

  • Fixed application log file name format.

  • Application log file now uses UTF-8 encoding (with BOM).

  • Replaced function call for setting bitrate in Kvaser interfaces to fix bitrate issues in some trucks

  • Snapshots:

    • TXT and XML files now contain an UTC timestamp that is formatted according to ISO 8601.

    • Added a node for application name and version to the XML file.

    • New version 3.0.0 of XML schema (XSD).

    • Adjusted the XSL transformations to match the changes made to the *_OBD.xml files in in an earlier release.

    • Bugfix: Missing comments added to the list of supported DIDs in the output files.

  • J1699-3 test: Model years can now be selected up to 5 years ahead.

  • List of standardized DTCs updated

  • SAE J1979:

    • Allow to record J1979 Mode 1/9 or 1/6/9 simultaneously

  • SAE J1979-2:

    • Bugfix: Data could have been assigned to the wrong ECU under certain conditions

    • 'Rationality' page disabled as it is only used for SAE J1939

    • Performance improvements when displaying a large number of DTC-based data

  • SAE J1939:

    • Several data stream SPNs added to config file


7.64.44.59120 Release (2024-10-10)

  • Added an option to immediately create a HTML file with a snapshot

  • Added an options page for the PDF page layout settings

  • Highlight test results in the XML to HTML/PDF creation

  • Fix display of ECU read and fault code read status the XML to HTML/PDF creation

  • Bugfix: "Copy data to clipboard" for RX-Messages in send diagnostic services

  • Bugfix: After the last Excel update, Excel crashed when writing comments

  • Automatic bitrate detection for 250/500 kbps on ISO 15765

  • SAE J1979:

    • PID AD updated

  • SAE J1979-2:

    • Configuration file completely updated along SAE J1979-DA

    • DIDs for China ZEV requirements added


7.63.44.58911 Bugfix Release (2024-09-19)

  • Bugfix: Adjusted parser for S19/MOT flash files.

  • Change: FlexRay Extended CAN ID request/Response changed to offset +0x2000

  • SAE J1979:

    • Bugfix: Sometimes display values data were duplicated

    • Bugfix: XML output of binary data (PID 01, PID 03) could be duplicated under certain conditions

  • SAE J1979-2:

    • Data for Bank3/4 in DIDs F406-F409, F455-F458 temporarily deactivated to show data correctly in Freeze-Frame

  • SAE J1939:

    • Several data stream SPNs added to config file

    • Missing SLOTs added to config file



7.63.44.58624 Release (2024-08-12)

  • CAN output:

    • Added support for sending OBD Mode 6

    • Added support for sending complete OBD from Mode 1 to Mode A

    • Bugfix in UDS. The error appeared only for a few values related to the battery.

    • Added support for sending simultaneously Mode 1/6/9.

  • Added configurable sleep interval in send diagnostic services

  • Automatic baud rate detection for OBD protocols on CAN with Kvaser interfaces

  • SAE J1979:

    • Conversion of PID B5 fixed

    • Conversion table for PID 1C updated

  • SAE J1979-2:

    • Conversion of DID F4B4 fixed

    • Conversion table for DID F41C updated

    • Use DID F501 to retrieve MIL-status if supported

  • SAE J1939:

    • Configuration file updated along SAE J1939-DA from June 2024

    • Many data stream SPNs added to config file according to MY 2027 EPA


7.62.44.58318 Bugfix Release (2024-06-26)

  • Bugfix: IXXAT/HMS interfaces didn't work in previous release

  • Improved message for physical connection errors on the CAN bus

  • SAE J1979:

    • PID AC and PID D4 fixed for Mode 1/2

    • Output of PID 7A fixed: User interface, recording, snapshot and CAN output

    • Recording and snapshot for Mode 9 IUMPR data fixed for ECUs that report both Infotype 08 and 0B

  • SAE J1979-2:

    • Unit and Scaling IDs for test results updated according to latest SAE J1979-DA

    • XML output for DTC based data improved

    • Configuration file updated: Binary StatusOfDTC added, several unneeded data items removed


7.62.44.58090 Release (2024-05-28)

  • Performance improvement when displaying fault memory and ECU identification

  • Enable FlexRay for OBDonUDS protocol

  • The serial number of the interface has been removed from the display name for communication channels 

  • BREAKING: Web services that set the communication channel via the name may need to be adapted.

  • Selection of OBD Scantool PIDs has been changed from a separate form to a list next to the displayed values

  • List of DTCs updated along SAE J2012-DA from March 2024

  • SAE J1979:

    • PID AC and PID D4 fixed in Mode 1/2

    • PID DB and DC added to Mode 1/2

    • Infotypes 81-90, 96 and A3-A8 added to Mode 9

  • SAE J1979-2:

    • Many new DIDs added to config file

    • Supported DIDs in the range of F4xx and F5xx are detected separately

    • Bugfix: Freeze-Frames have not been requested correctly under certain conditions

    • Implementation of DoIP in progress but not yet finished

    • Failure Type Bytes updated along SAE J2012-DA from March 2024

  • SAE J1939:

    • Configuration file updated along SAE J1939-DA from February 2024

    • Several data stream SPNs added to config file

    • Several improvements in SAE J1939 CAN transport protocol to fix missing SPNs and freezing snapshot

    • Table view in communication monitor fixed